Skip to content

IT focus graph wrong % calculation (#2441)

Symptom

A unit with 11.5 t total footprint and ~1.2 t IT footprint saw "90%" as the IT share, and the waffle almost fully coloured. Separately, the IT total big number read "1 t" while its category parts read 0.8 + 0.4.

Root cause

derive_report_sections (backend/app/utils/report_stats.py) computed percentage_of_source_modules as validated IT kg ÷ the validated totals of only the four IT source buckets (equipment, purchases, research facilities, cloud & AI). A unit whose four source modules are mostly IT therefore showed a near-100% share regardless of buildings, travel, process emissions, etc.

The "1 t vs 0.8 + 0.4" mismatch was display rounding: formatTonnesCO2 renders one decimal below 1 t but zero decimals at ≥ 1 t, so exactly 1.2 rendered as "1".

Fix

  • Denominator is now the validated total across all buckets (sum of buckets[key].total_kg for key in validated_buckets), matching the Results headline total and the existing hint "Based on validated categories only". Numerator (validated IT kg) unchanged.
  • The stat is renamed percentage_of_validated_total; the old name would have lied about the new semantics. Renamed end-to-end: report_stats.py, frontend/src/utils/emissionStatsAdapter.ts, frontend/src/stores/modules.ts, ItFocusSection.vue, ItFocusBreakdownChart.vue, and the simulator integration mocks.
  • ItFocusSection.vue formats the IT total with up to one decimal (nOrDash with maximumFractionDigits: 1) so the total visibly equals the sum of its parts.

Operational note

The percentage lives in persisted carbon_report.stats; existing reports show 0% (field absent) until a backoffice recompute refreshes their stats.